Problem:
One of our customers got an error message when use the VXDIAG VCX FD as a passthru with Subaru FlashWrite software.
“Error: License invalid. Please update VCI.” and “4046 Error occurred in the Pass-thru device.”
Here is the clue.
To use VXDIAG VCX FD as a passthru, you have to activate the corresponding software license. For example, GM license for techline connect SPS2 programming,
So if you need to use VCX FD as passthru for Subaru, you have to activate Subaru license.
However the Subaru license is not yet ready for the VCX FD. VCX FD now only compatible with GM and Ford/Mazda license. Other software licenses are not integrated into the vcx fd yet.
But you can use VXDIAG VCX SE or VCX DoIP device with Subaru license with with Subaru FlashWrite software.
Problem:
One of our customers reported he could not start the ISTA-P 68.0.800 software from vxdiag VCX SE BMW software HDD.
ISTA-P gave a fault code: unable to start a new session.
There is an ‘ISTA-P FIX‘ program on the desktop.
Run the Fix tool and recover ISTA-P and run software again. It should be fine.
www.vxdiagshop.com
Question:
When starts BMWCoding Database program of the vxdiag vcx SE BMW software HDD on the desktop, it asks for an user name and email. Where to get user name?
We don’t provide user name and email. You should have your own login account (subscribe to BMW Coding Database).
BMW Coding Database is a collection of coding values and instructions that can be used to customize BMW vehicles through software upgrades.
BMW Coding Database is a comprehensive tool designed to assist BMW car enthusiasts with customizing and reprogramming various functions in their vehicles. This database provides access to relevant codes and procedures needed to make modifications to a BMW’s electronic control module (ECM), including features such as comfort access, alarm settings, lighting options, and much more.
The cost to subscribe to BMW Coding Database varies based on the length of the subscription and the specific package selected.
It is a Toyota Raize 2020. The customer wants to add a new spare smart key to it. 4A HitagAES smart key.
4A HitagAES status “already locked”. The customer purchased a new key (the
key looks exactly the same as the original, both internally and externally). The
new one had the status “already locked”, the same picture with the ID47 Hitag3
keys on the Tank (and all cars of the same platform), which did not interfere
with programming this key to the car.
Everything is clear with the key. Let’s
move on.
We use through TechStream 18 and a techstream cable (vxdiag
vcx nano Toyota or Mangoose JLR, no MINI VCI cheap cables).
Choose the Toyota Raize 2019-2021 model and there is nothing there.
neither Body, nor Immo, nor enrty&start function.
Try to do it through Tank. Choose a Tank body M900 engine 1kr and year of manufacture 2016-2018.
Here we choose Body and then Utilities.
Go to Body, everything is fine, the module responds, then go to
Utilities and select “add Key” from the list. If you select “add new key”
nothing will work.
Well, that’s it, we operate according to the
instructions. With the ignition on, turn off all additional devices, leave one
door open – bring the attached key to the button, the car beeps – then bring the
new key and ! click next!
Then the car will click the locks. You can all click Exit to complete
the procedure or click Next to program the next key.
That’s it,
the key is ready. Everyone is happy.
One of our customers tried to program a Nissan Qashqai J11 MY2013 ECU
engine module with VXDIAG
VCX SE Nissan device and online
subscription.
During the programming procedure, the Consult3+
software stuck and failed to program.
Try again but still the
same problem.
Consult finds 2 firmware updates for the engine.
This is where everything froze, waited for the promised 15 minutes for about an hour or a little more. No luck. Try again still same problem.
Solution:
VCX does not support online programming for
Nissan pre-2010. 2010-2013 need luck. 2013 onwards Nissan has no problem with
online subscription.
But you need a proper Consult 3 plus version.
Version V226 is not
recommended for programming (a few reported the software will get stuck during
the programming procedure).
Version V235 fixed the programming
issue.
If you need V235 software, contact our customer service to
send you a download link (provide order number and VCX