VXDIAG DTS Monaco Not Working After Turn on DoIP Switch?

Problem:

I got the latest vxdiag vcx se benz c6 driver updated and turn on the DoIP switch. DTS Monaco is not working, won't program HU5. DoIP switch disconnected after several minutes. Any solution?

VXDIAG DTS Monaco Not Working After Turn on DoIP Switch 1


VXDIAG DTS Monaco Not Working After Turn on DoIP Switch 2


VXDIAG DTS Monaco Not Working After Turn on DoIP Switch 3


VXDIAG DTS Monaco Not Working After Turn on DoIP Switch 4

Solution:

Don't need to turn on DoIP switch when running DTS Monaco engineering software.

DoIP switch is used when diagnosing DoIP models with Xentry program.

Test if the Doip switch will disconnect when run Xentry software, if yes, contact vxdiagshop.com technical support to check it on Teamviewer.

How to configure Monaco 8.16 to use VXdiag vcx se benz doip?

Question: Does anyone have Monaco 8.16 config to use VXdiag vcx se benz doip? I can get the VXDIAG to work over CAN bus but not DoIP. I don't show or can't select the same D-PDU API version? Is there something I'm missing?

VXDIAG DTS Monaco Cannot Select D-PDU API Version 1

Solution:

Do the following settings:

VXDIAG DTS Monaco Cannot Select D-PDU API Version solution 1

VXDIAG DTS Monaco Cannot Select D-PDU API Version 2

Check if DTS version is 8.1.6.15.

If it's 8.16.15, check is your DTS software is installed with complete Addons.

If no then you got to get proper DTS 8.16 and installation files.

Check step-by-step configuration guide here: How to set up DTS Monaco 7.1.6 with VXDIAG VCX SE

Mercedes W205 Start/Stop Coding with VXDIAG DTS Monaco

Mercedes Benz W205 Start/Stop coding tutorial using vxdiag vcx se benz or benz c6 doip with DTS Monaco 8.14.

 

 

Requirement:

VXDIAG uses DTS 8.13 and here we use DTS Monaco 8.14.

You should download SMR-D files for connection and SeedCalculator. Download free here.

 

Everything you do is at your own risk. We are not responsible for the damage. 

 

 

Disable Start/Stop in W205 with DTS Monaco 

1. Turn on the ignition. Launching DTS Monaco

select Temporary workspace
VXDIAG DTS Monaco Disable Benz W205 Start/Stop 1


 

2. Select the SMR-D file from the list, depending on which module you want to connect to. in our case, MED40.

3. Remove the module from the control unit. In the Diagnostic service tab, we find the Security Access line, find the Request seed key line in the list, click on the Transmit button. We get the key, which we enter in SeedCalc.

VXDIAG DTS Monaco Disable Benz W205 Start/Stop 2


 

See the same code below. We copy it.

4. Run SeedCalc. At the top, select MED40CNG_med40_sec_new_00_00_00.

VXDIAG DTS Monaco Disable Benz W205 Start/Stop 3

In the screenshot SeedCalc 2.3, but I give a link to the 3rd version. Works identically and the logic is the same.

5. In the "SEED" field, enter the values ​​obtained from the Request seed key at the previous stage. Click "Generate". Copy the first 8 characters (all except 00 00 00 00).

6. Go to DTS Monaco. Select the line Send Key Variantcoding. On the right, in the "Send key" field (highlighted in green), paste the data received from SeedCalc.

VXDIAG DTS Monaco Disable Benz W205 Start/Stop 4

6.1. Click on the Transmit button. If the code is correct, then below it will be " acknowledged ".

VXDIAG DTS Monaco Disable Benz W205 Start/Stop 5

IMPORTANT! If, when sending a seed code, the Response State is marked in red and written not acknowledged, then you need to select another module option in SeedCalc and calculate the code again. The unlock code changes after each entry. Those. if the unlock code did not fit, then you need to select Request seed key again and insert new values ​​into SeedCalc.

7. If everything is successful at this stage, then go to the "Variant coding" tab. In the ECU selection menu, find MED40 and click "Connect". Scroll down, find the desired line and change to "Last mode". Then click on Do Coding! In this way, you can change the speed limiter and in general everything that is in the MED40.

VXDIAG DTS Monaco Disable Benz W205 Start/Stop 6

8. After you have done the encoding, you need to return to the Diagnostic service, select Hard reset and click Transmit.

Now start / stop remembers the last position and does not turn on automatically when switching between sport-eco-comfort modes and does not turn on when starting the car. Those. the start-stop system is in the state it was in before the engine was turned off.

The same logic encodes all other units that support variant encoding.

http://blog.vxdiagshop.com/2022/05/31/vxdiag-vcx-se-with-dts-monaco-doip-configuration/

Set up VXDIAG VCX SE Benz or Benz C6 with DTS Monaco 8.14

To add some information for those who wanna set up VXDIAG VCX SE Benz or Benz C6 with DTS Monaco 8.14 (most stable cause above may not work yet), you need to set up as described in the picture by adding new interfaces and enter the described parameters manually.

DoIP interface:

Interface name; ISO_DoIP-SMR

Bus system interface: D-PDU API

D-PDU API version: Bosch Automotive Service Solutions BOSCH-DS_D_PDU_API_FOR_DTS_8.13_029

Module type: MVCI_DAIMLER_DOIP_Collection

Cable: J1962-CARB

Tick use for licensing 

Physical links:
IEEE 802_3 (1 TX, 9 LOW, 12 RX, 13 MINUS) Ethernet 2
IEEE 802_3 (3 TX, 11 LOW, 12 RX, 13 MINUS) Ethernet 1

 

CAN Interface:

Interface name: VCI_DoIP

Bus system interface: D-PDU API

D-PDU API version: Bosch D_PDU_API_Bosch_MTS6532

Module type: Module_Type_ID_MTS6532

Vendor module name:87517478

Cable: OBD_STDCABLE_ONLY

Tick use for licensing 

Physical links:
ISO 11898 2 DWCAN (6 HI, 14 LOW) CAN 1

VXDIAG DTS Monaco DoIP Configuration

Read also:

How to Set up DTS Monaco 8.16 with VXDIAG VCX SE Benz C6?