Great news! The VXDIAG VCX SE 6154 and VCX NANO 6154 have released a new driver update to support the latest ODIS Service 24.x software.
2025.02.27 v3.4.2.250227
What's New:
Update: Added driver support for the new ODIS 24.x software version.
Fix: Resolved an issue causing DoIP diagnostic crashes in the latest software.
Update VW ODIS 6154 driver in VX Manager.
Problem:
Tried using the VXDIAG VCX SE Benz with third-party Benz Xentry software. During the setup, I attempted to install the Benz C6 driver in the VX Manager, but the installation failed. The error message indicated that the Xentry diagnosis software was not installed. Any ideas on how to fix this?
Solution:
After a TeamViewer session, we discovered that
the original Bosch driver was
missing. Once the Bosch driver was installed, the issue
was resolved, and the setup worked correctly.
Steps to Fix:
Problem:
I tried setting up the VXDIAG
VCX SE with Volvo VIDA 2014D software on Windows 10. After
running VIDA from the patch, I was unable to log in. I reinstalled the software,
but the issue persisted. Any ideas on how to resolve this?
Solution:
After a TeamViewer session with an engineer from Vxdiagshop.com, it was discovered that the wrong patch was being used.
Steps to Fix:
Problem:
Tried to use VXDIAG VCX SE 6154 scanner with the new ODIS service software version 24.3.2. VX Manager detected the interface but no VCI selection in ODIS software.
Does vxdiag work with odis 24.3.2?
Solution:
The vxdiag vcx se is compatible with 24.3.2 service software.
1. Update VW driver. Uninstall VW ODIS 6154 and reinstall driver in vx manager.
2. Install ODIS PDU driver.
The original 6154 driver is lost or hacked by virus.
Contact www.vxdiagshop.com to download original ODIS-S PDU driver (VW D-PDU API 64bit).
Double-click to install the VW D-PDU API 64bit driver setup. Choose the destination location as C:/Program Files/VW_PDUAPI_OS folder and wait until the setup installation is finished.
It should be fine. Run ODIS-S software again. Select VCI type as VAS 6154.
Problem:
Tried to use VXDIAG VCX SE GM with GM Techline Connect SPS2 for ECM programming. TLC reported an error “UEH101:null”. Anyone gotten this error before?
Solution 1:
Delete it and reinstall happened to some others.
If hit uninstall then redownloaded. Same problem. You have to uninstall everything that involved it’s. There’s like 15-20 different things that tie in to it. Have to go to add remove programs and remove it all.
Solution 2:
Had this happen not too long ago called tech support and 3 hours later they said it was my computer. New laptop. I was using google chrome to sign in to tds, but when I switched to Microsoft edge I worked and went through and working ever since. Hope you get it resolved!